SETTING THE CHAIN COUNTER
EN
SETTINGS
PERSONAL SET
UTILITY
CAN CONFIG
EXIT
COUNTER RESET
ARE YOU SURE?
YES
NO
FUNCTIONS
UP ALARM
AUTO DOWN
EXIT
SETTINGS MENU - FUNCTIONS - UP ALARM
Use this option to set or disable the up alarm. This function stops the anchor from moving up and informs the user when
the length of the chain lowered is less than the set value.
ATTENTION: the up alarm function is active only by using a chain counter CHC1103 controls when the anchor
moves up. It does not function if the anchor is moved up by any other remote control or a switch.
ATTENTION: the chain counter is not able to compensate for mechanical inertia of the windlass (the gypsy can
rotate upward direction as soon as the command has been inactivated). Take this factor into consideration when
setting the up alarm value.
ATTENTION: the alarm is displayed only once, if the chain measure lowered than the alarm threshold.
ATTENTION: leven if the up alarm is enabled, the user must always pay careful attention and make sure the anchor
is correctly pulled up.
UP ALARM
SET VALUE:
OFF
UP ALARM
SET VALUE:
OFF
SETTINGS MENU - FUNCTIONS - AUTOMATIC DOWN
The automatic down function is enabled or disabled with this option. This function allows the anchor to automatically
move down to the set depth (see chapter CHAIN COUNTER OPERATION paragraph AUTOMATIC DOWN FUNCTION).
ATTENTION: the chain counter is not able to compensate for mechanical inertia of the windlass (the gypsy can
rotate downward direction as soon as the command has been inactivated). Take this factor into consideration when
setting the automatic down value.
ATTENTION: even if the automatic down function is enabled, the user must always pay careful attention and make
sure the anchor is correctly lowered.
32
If a SLAVE chain counter is being used without the MASTER in the CAN network, the following
"reduced" settings menu will be displayed:
These submenus have particular parameters and functions for every single counter which can
not be shared with other chain counters present on the CAN network.
SETTINGS MENU - COUNTER RESET
Use this option to reset the measure of chain lowered. This option is to be used during in-
stallation or when the chain counter's reading does not match the actual length of the chain
lowered.
YES or NO can be selected.
SETTINGS MENU - FUNCTIONS
Use this option to activate and set the up alarms and automatic down.
Examples of the windows used for the up alarm are shown below:
default: OFF
If the unit of measurement is set to METERS, the settable values are:
OFF, 1.0M, 1.5M, 2.0M, 2.5M, 3.0M, 3.5M, 4.0M, 4.5M, 5.0M.
If the unit of measurement is set to FEET, the settable values are:
OFF, 3.0FT, 4.5FT, 6.0FT, 7.5FT, 9.0FT, 10.5FT, 12.0FT, 13.5FT, 15FT.
CHC1103 IT EN FR - REV001A