CONFIRMATION MESSAGES
Confirmation messages that may appear on the state line are shown below.
Stop
STOP
STOP
When no commands are sent to the windlass, the following window is displayed:
35.3
M
SPEED
0M/M
Memory stored
MEMORY STORED
As soon as four seconds elapsed from the last operation was completed (up, down, automatic
35.3
down, free fall), the chain counter stores the length of the lowered chain in the EEPROM memory.
M
The window shown below is displayed while the data are being saved:
SPEED
0M/M
Locked Controls
LOCKED
Once the time set in the LOCKED KEYS parameter has elapsed, the instrument will inhibit the func-
35.3
tionality of the
M
ing the
SPEED
0M/M
MAINTENANCE
The chain counter does not require any particular maintenance. To assure top performance, check the cables and electri-
cal connections once a year.
Clean the chain counter with a soft rag dampened in water. Do not use chemicals or harsh products to clean the chain
counter.

TECHNICAL DATA

OUTPUT CHARACTERISTICS
UP/DOWN contacts current
INPUT CHARACTERISTICS
Supply voltage (1)
Current absorbed when idling (2)
Maximum current absorbed (3)
AMBIENT CHARACTERISTICS
Operating temperature (4)
Degree of protection (5)
GENERAL CHARACTERISTICS
Communication interface
Weight
EMC class
(1) The chain counter can reset itself if the voltage is less than 9 Vdc.
(2) Typical value with back-lighting off and windlass not on.
(3) Typical value with back-lighting on at highest level and windlass on.
(4) With temperatures below 0°C the crystals in the LCD slow down.
(5) With the plug correctly inserted into the socket. Excluding the area of the socket where the exit cable is fixed (IP 00).
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
®
CHC1103 IT EN FR - REV001A
SYSTEM FAULT - MAINTENANCE - TECHNICAL DATA
p
q
and
and (UP and DOWN) keys; pressing these keys will have no effect. Press-
=
key (SELECT) will reactivate the functionality of the
p
and
4A max
9 ÷ 32 Vdc
31 mA @ 12V - 18 mA @ 24 V
85 mA + current used by solenoid unit
from -20 to +70 °C
IP 67
CAN BUS with differential transceiver
750 g
EN 60945 - FCC Part 15 Rules 47
q
(UP and DOWN) keys.
EN
39