Sensor switches ON/OFF for
no discernable reason
Sensor switches on
incorrectly
Changes/fluctuations in
range
Switched lamp is in the detection
range
Animals in the detection range
Nearby reflective surfaces trigger
switching
Wind is moving trees and shrubs in
the detection range
Detection of cars on the road
Sunlight is falling on the lens
Sudden changes in temperature due
to weather (wind, rain, snow)
Exhaust air from fans, open windows
Change in ambient temperature
Sensor/detection range is oriented
too steeply downwards
Rain, fog, or humid air
Direct approach
Cover area
Relocate or cover area
Readjust detection range
Realign detection range
Realign detection range
Install sensor in a protected area
Install sensor in a protected area
Relocate installation site
Reset detection range
Realign motion detector
Install motion detector in a protected
area
Install the device so that the subject
passes through the detection range
transversally from the main direction
of approach
D