Technical data
Nominal voltage:
Permanent current:
Starting current:
Switching contact
Frequency:
Detection angle:
Number of levels:
Detection range first level:
Detection range second level:
Recommended installation height:
Duty cycle:
Twilight threshold:
Connection equipment:
Switching capacity:
Incandescent lamp:
Halogen lamp:
Fluorescent lamp:
Fluorescent lamp:
Inductive loads:
Optional RC component (2915.0004.3): 100nF / 100Ω. parallel to the inductive load
Operating temperature:
Degree of protection:
230V~; +- 10%
10 A
16 A (maximum 0.4 seconds)
µ
50 Hz
140°/100°
2
ca. 10 m
ca. 4 m (crawl protection)/detection angle 100°
2,5 m
infinitely adjustable from 4 – approx. 240 seconds
Night (moon) / Day (sun)
3-wire (L, N, arrow or connection with lamp symbol)
2,000 W (resistive load)
max. 1000 W
max. 1000 W
max. 130 W (parallel compensated)
max. 1500 W (series compensated)
max. 5A at cos phi 0.5
–25 °C t +55 °C
IP 54