Télécharger Imprimer la page

Kopp INFRAcontrol 3D Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

the housing.
• Insert the rubber grommet for the cable entry and feed
the connection wires through.
• The cable entry points must be absolutely water-proof.
• Break through the marked condensation water opening
• Make the electrical connection.
• Attach the front cap and screw together.
Electrical connection
Connect the wires and lamp wires as follows:
See wiring diagram (table)
Phase L on luster terminal Brown
Neutral wire N luster terminal Blue
Connecting wire luster terminal Black
The motion detector is immediately ready for operation
upon connection to the power supply.
Connection of consumers
High starting currents severely reduce the useful life of
relays. For this, follow the technical instructions of the
lamp or light manufacturer.
High inductive loads should be switched by means of an
additional relay or an additional contactor.
ò
.
brown
blue
black
Setting the twilight threshold
Carefully remove the front cap with a screw driver, for ex-
ample (see illustration).
Set the desired brightness value with the adjustment
screw. In case of direct sunlight, the brightness value is
above the setting value, meaning that the motion sensor
no longer reacts.
• Adjustment screw to the stop on the right side means:
day operation
• Adjustment screw to the stop on the left side means:
night operation
D
GB
NL
N
230 V/50 Hz
L
F
I
P
17