Technical Data; Accessory - Riello RL 55/M BLU Manuel D'entretien

Table des Matières

Publicité

TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
FUEL
- net calorific value
- density
- viscosity at 20 °C
OPERATION
NOZZLE
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
PUMP
delivery (at 20 bar)
pressure range
fuel temperature
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(2)
APPROVAL
Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(2)
ACCESSORIES (optional):
• OUTPUT MODULATION REGULATOR KIT
Two components should be ordered:
output regulator to install on the burner;
probe to install on the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
• DEGASSING UNIT
It may occur that a certain amount of air is contained in the light oil sucked up by the pump. This air may originate from the light oil itself as a
consequence of depressurization or air leaking past imperfect seals.
In double-pipe systems, the air returns to the tank from the return pipe; in single-pipe systems, the air remains in circulation causing pressure variations
in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the burner in single-pipe installations.
Degassing units are provided in two versions:
CODE 3010054 without filter
CODE 3010055 with filter
- Burner delivery
- Light oil pressure
- Ambient temperature
- Ambient temperature
- Light oil temperature
- Light oil temperature
- Attachment connectors
For burner deliveries higher than 80 kg/h, install two parallel degassing units
MAX.
kW
Mcal/h
kg/h
MIN.
kW
Mcal/h
kg/h
kWh/kg
Mcal/kg
3
kg/dm
2
mm
/s
number 1 (nozzle with return)
°C
°C max 60
V
Hz
rpm
W
V
A
V1 - V2
I1 - I2
kg/h
bar
° C max
W max
dBA
Range
- 100...+ 500 °C
0...2,5 bar
0...16 bar
: max. 80 kg/h
: max. 0.7 bar
: max. 50 °C (without filter)
: max. 40 °C (with filter)
: max. 50 °C (without filter)
: max. 40 °C (with filter)
: 1/4 inch
RL 55/M BLU
969 T
356 - 712
307 - 614
30 - 60
190 - 356
164 - 307
16 - 30
LIGHT OIL
11.86
10.2 (10.200 kcal/kg)
0.82 - 0.85
max 6 (1.5 °E - 6 cSt)
• On-Off (min 1 stop each 24 hours). These burners are also fiitted for the
continuous operation, if they are equipped with the control box LANDIS
type LOK 16.250 A27 (interchangeable with the burner control box LAN-
DIS LAL 1.25).
• Progressive two-stage (modulating by Kit)
Boilers: water, steam, diathermic oil
0 - 40
230 - 400 with neutral +/-10%
50 - three-phase ~
2800
1800
230 - 400
220/240 - 380/415
7.4 - 4.3
230 V - 2 x 5 kV
1.9 A - 30 mA
163
10 - 21
90
2200
IP 44
89/336 - 73/23 - 98/37
78.5
PROBE
Type
Code
PT 100
3010110
Probe with output
3010213
4...20 mA
3010214
6
RL 85/M BLU
952 T1
594 - 1023
512 - 882
50 - 86.2
223 - 594
192 - 512
18.8 - 50
2800
2200
8.5 - 4.9
2600
78.5
POWER REGULATOR
Type
RWF40
GB
Code
3010212

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rl 85/m blu969 t952 t138992003896010

Table des Matières