DESCRIPTION OF THE PRODUCT
2

OPERATOR FEATURES

DINGO operators are constructed to form part of a
sliding gate automation system.
This operator, with built-in control panel, is equipped
with a slowdown system which reduces speed at the
end of the opening and closing operations, in order to
prevent impacts and bangs to the gate.
General characteristics
• DNS424E: Power supply 230Vac, 50Hz earthed
• DNS424EM:Power supply 125Vac, 60Hz earthed
• Control of open/close by way of encoder
• Variable pinion height
• Adjustable speed
• Adjustable maximum force
Notable characteristics
Self-testing of photocells (programmable)
The control panel tests the photocells before starting
each operation. Should a failure be detected, the
operation is not carried out.
Garage light (programmable)
The garage light time can be programmed between 3
and 240 seconds. Time begins to count when the
operation starts.
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Operation pre-warning function
(programmable)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn that operation is about to begin.
Traffic light
A traffic light can be connected if the AEPS1-001 card
is installed. Colour lights show whether the gate may be
crossed or not.
• Off: Gate closed
• Green light: gate open, free to pass
• Red light: gate in movement, forbidden to pass
• Flashing green light: open gate about to close (in
automatic mode)
44
Installation Guide
This operator allows us to fulfil the requirements of
standard EN 12453 without the use of peripheral
elements.
• Adjustable standby time in automatic cycle
• Opening and closing safety device cable connectors
(safety strips or photocells)
• Connector for plug-in receiver
• Connector for traffic light card (AEPS1-001)
• 24Vdc cable connector for peripheral connection
• Emergency battery input
SCA Light
A 24V SCA light can be connected.
• The light remains off when the gate is closed.
• The SCA light remains on without flashing when the
gate is open.
• During opening, the SCA light flashes every second.
• During closing, the SCA light flashes every half a
second.
Slowdown function (programmable)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
24Vdc battery (bA)
It is possible to connect a battery in order for the
operator to continue working in the event of a drop in
power. The battery will be recharged when the
electricity supply is restored.
Reset (rS)
Reset is the closed gate position search at slow speed.
The display shows rS.
The operator carries out a reset in the following cases:
• When the electricity supply is restored following
interruption, and a key device is activated
• When the operator for manual operation is
unlocked and locked again
• When the gate collides with an obstacle three
consecutive times