OPERATION MODES

Automatic mode (F101)
Opening: This begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Collective opening: the control board does not
obey
the
key
(configurable in the advanced options menu, see
"Advanced Functions Programming (D1= "A")" on
page 57).
Step-by-step mode (F102)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening: if the key device is operated
during opening, the gate stops (programmable in
the advanced options menu, see "Advanced
Functions Programming (D1= "A")" on page 57).
The display shows pause situation
The gate closes when the key device is activated again.
5

OBSTACLE DETECTION FUNCTIONING

The gate can detect an obstacle in two ways:
A- Detection by photocell or strip
Opening safety device (SG.A)
During opening: if the opening safety device (SG.A) is
activated during opening, the gate inverts operation
direction and slightly closes. The gate remains on
standby until a key command is received and the display
shows PAC4.
During closing: if the opening safety device (SG.A) is
activated during closing, the gate continues to close.
B- Direct detection (built-in safety)
During opening
If the gate collides with an obstacle during opening, it
inverts operation direction and slightly closes. The gate
remains on standby until a key command is received
and the display shows PAF1 or PAE1. The gate closes
when the key device is used.
46
Installation Guide
commands
during
opening
PA
.
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• If the key device or the photocells are activated
during standby, standby time restarts (configurable
in the advanced options menu, see "Advanced
Functions Programming (D1= "A")" on page 57.
Closing: the closing operation starts automatically
once standby time is finished.
If the key device is activated during closing, the gate
inverts operation direction and opens completely.
Standby: the gate remains open indefinitely until the
key device is operated.
Closing: the closing process starts up by using the key
device.
If the key device is activated during closing, the
operator inverts the movement and the gate opens.
Closing safety device (SG.C)
During opening: if the closing safety device (SG.C) is
activated during opening, the gate continues to open.
During closing: if the closing safety device (SG.C) is
activated during closing, the gate inverts operation
direction and opens completely. The display shows
OPC5.
During closing
If the gate collides with an obstacle during closing, it
inverts operation direction and opens completely. The
display shows OPF1 or OPE1.