TECHNICAL DATA
Cable Cutter
Production code
Battery voltage
Nominal force
Cutting range Depends on cable type
Insulated copper / Aluminum cable, lightly
reinforced
Weight according EPTA-Procedure 01/2003
(Li-lon 5,0 Ah)
Noise information
Measured values determined according to EN 62841. Typically, the
A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=3dB(A)) 73,5 dB (A)
Sound power level (Uncertainty K=3dB(A))
Wear ear protectors!
Vibration information
Vibration total values (triaxial vector sum) determined according
to EN 62841
Vibration emission valuea
h
Uncertainty K=
WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric
shock, re and/or serious injury.
Save all warnings and instructions for future reference.
CABLE CUTTER SAFETY WARNINGS
To reduce the risk of explosions, electric shock and damage to
property and equipment, never cut live electrical cables. Tool is
NOT insulated.
Keep hands and loose items of clothing away from cutting tools
and other moving parts. There is a risk of serious injury, including
severing of limbs.
The use of protective clothing is recommended, such as dust
mask, protective gloves, sturdy non-slip footwear, helmet and ear
defenders.
Use protective equipment. Always wear safety goggles when
working with the cable cutter.
Prevent accidental starting of the cable cutter. Before connecting
to a removable battery, ensure that the trigger is secured with the
switch lock.
Never hold the cable cutter by the cutting jaws.
RESIDUAL RISK
Before the cutting process begins, access must be sealed o in
accordance with local regulations.
Only ever cut cables that have been disconnected from the power
supply.
Deutsch
WARNING!
M18 HCC75
The vibration emission level given in this information sheet has been
4587 10 01...
measured in accordance with a standardised test given in EN 62841
... 000001-999999
and may be used to compare one tool with another. It may be used
18 V
for a preliminary assessment of exposure.
77,8 kN
The declared vibration emission level represents the main
max. Ø 75 mm
applications of the tool. However if the tool is used for di erent
applications, with di erent accessories or poorly maintained, the
vibration emission may di er. This may signi cantly increase the
exposure level over the total working period.
7,9 kg
An estimation of the level of exposure to vibration should also take
into account the times when the tool is switched o or when it is
running but not actually doing the job. This may signi cantly reduce
the exposure level over the total working period.
Identify additional safety measures to protect the operator from
the e ects of vibration such as: maintain the tool and the acces-
84,5 dB (A)
sories, keep the hands warm, organisation of work patterns.
0,2 m/s
2
1,5 m/s
2
Before using, always check the cutting jaws for cracks and other
signs of wear.
Only use the cable cutter, removable battery and charger if they are
in perfect technical condition.
Have damage repared immediately by an authorised workshop.
Remove the battery pack before starting any work on the
appliance.
The cable cutter may only be used with a cutting tool inserted.
Remove any setting tools and wrenches before making the cut.
To avoid injury and damage, never immerse the tool, removable
battery or charger in liquid or allow liquid to penetrate them.
Hold the cable cutter by both handles.
In the event of faults during the cutting process, release the trigger
immediately and press the hydraulic reset button.
The valve will open and the piston will return to its initial position.
Failure to comply with this instruction can lead to serious injury,
death, re and other damage to property as a result of electric
shock, explosion and/or electric arcs.
Wear goggles.