Safety Instructions - Hilti PD 42 Mode D'emploi

Masquer les pouces Voir aussi pour PD 42:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Technical data
Beam diameter
Basic operating modes
Display
en
Laser
Optical sight
Automatic cut-out
Battery life
Operating temperature range
Storage temperature
Protection class (except battery compartment)
Weight without batteries
Dimensions
Menu / units
m
cm
mm
In
In ¹/₈
In ¹/₁₆
In ¹/₃₂
Ft
Ft ¹/₈
Ft ¹/₁₆
Ft ¹/₃₂
Yd

5 Safety instructions

In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.1 Basic information concerning safety
a) Do not render safety devices ineffective and do
not remove information and warning notices.
b) Keep laser tools out of reach of children.
c) Failure to follow the correct procedures when open-
ing the tool may cause emission of laser radiation in
26
Distance
Meters
Centimeters
Millimeters
Inches, decimal
¹/₈ inch
¹/₁₆ inch
¹/₃₂ inch
Feet, decimal
Feet-inches-¹/₈
Feet-inches-¹/₁₆
Feet-inches-¹/₃₂
Yards, decimal
Values
Beam length 10 m: Max. 6 mm
Beam length 50 m: Max. 30 mm
Beam length 100 m: Max. 60 mm
Single measuring, continuous measuring,
calculation/functions
Illuminated dot-matrix display with permanent indica-
tion of operating mode and battery condition
Visible 635 nm, Output power less than 1 mW: Laser
Class 2: IEC/EN 60825-1:2007; Laser Class II CFR 21
§1040 (FDA)
Side-mounted, with laser reference
Laser: 1 min
Tool: 10 min
Max. number of measurements with laser beam
switched on for a time of 10 s Alkaline 8,000...
10,000 NiMH 6,000...8,000
-10...+50°C
-30...+70°C
IP 54 protection against dust and water jets
IEC 60529
170 g
120 mm x 55 mm x 28 mm
Area
Inches²
Inches²
Inches²
Inches²
Feet²
Feet²
Feet²
Feet²
Yards²
excess of class 2. Have the tool repaired only at a
Hilti service center.
d) Check that the tool functions correctly each time
before use.
e) Operation of the tool in the proximity of pregnant
women is not permissible.
f)
Measurements taken from surfaces with low reflectiv-
ity in highly reflective surroundings may be inaccur-
ate.
g) Measurements taken through panes of glass or other
objects may be inaccurate.
Volume
Inches³
Inches³
Inches³
Inches³
Feet³
Feet³
Feet³
Feet³
Yards³

Publicité

Table des Matières
loading