Maintenance And Care - Festo EGC-TB-KF Notice D'utilisation

Masquer les pouces Voir aussi pour EGC-TB-KF:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
EGC-TB-KF, EGC-HD-TB
8

Maintenance and care

Warning
Uncontrolled moving masses can cause injury to people or damage to property (squeez­
ing). If a toothed belt breaks in combination with a vertically or diagonally installed EGC,
the work mass will fall down.
• In case of signs of wear, return the EGC to Festo for repairs.
Controller signals can cause the EGC to make unintended movements.
• Switch off the controller for all maintenance work on the EGC and secure it to pre­
vent it from being restarted unintentionally.
On cleaning and maintenance:
• If required, clean the guide axis with a soft cloth. All media gentle to the material may be used as
cleaning agents.
Note
The lubrication interval S
• Cut the lubrication interval S
present:
– dusty and dirty environment
– nominal strokes  2000 mm
– at speeds  2 m/s
– positioning profile Z delta operation (frequent acceleration and braking)
– ambient temperatures  40 °C
– product has been in operation for  3 years.
If several situations occur simultaneously, the lubrication interval must be divided by
four.
• Grease the following components:
Lubricating point (è Fig. 1)
Lubrication interval
2)
Grease
1) or if the component no longer has a layer of grease
2) Grease gun, blast pipe and grease (è 10 Accessories)
Tab. 6
Festo – EGC-TB-KF, EGC-HD-TB – 1505b English
is dependent on the product load.
int
(è Fig. 12) in half if the following situations are
int
Bearing guide
Relubrication opening aB
(è Fig. 12)
Roller bearing grease
Guide rail
Surface 5
1)
As required
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Egc-hd-tb

Table des Matières