5

Installation

5.1

Mechanical assembly

• Do not modify the screws and threaded pins.
Exception: Direct request to do so in these operating instruc­
tions.
• Mount the motor onto the axis in accordance with the assembly
instructions for the motor mounting kit recommended in the
catalogue.
5.1.1

Mount axis

Requirements
• Position the product in such a way that its control sections are accessible (e.g. relubrication open­
ings).
• Make sure that the mounting components are outside the positioning range of the slide.
• Install product without tension or distortions.
• Fasten product to a mounting surface with flatness of 0.05 % of
the stoke length, but max. 0.5 mm.
For gantry applications, attention must also be paid to parallel
alignment or product heights in alignment of the axes.
For additional information, contact your local Festo Service.
• Take the required support spacing into account
(è 13 Characteristic curves).
• Attach the EGC (è Tab. 1).
Festo – EGC-TB-KF, EGC-HD-TB – 1505b English
Fig. 3
Fig. 4