9.
Clearing faults
DANGER! Electrocution!
▶ All devices must be disconnected from the power supply before clearing faults.
The LED light cannot be repaired. A defective appliance must be completely replaced.
Faults
LED light does not illuminate
(only incpiria marine)
Feed pump does not work
Feed pump runs dry
Water in the outflow shaft
lowers/rises
Cabinet light doesn't light
Cabinet light's remote control
doesn't work
For other faults, please contact EHEIM Service.
10. Decommissioning and disposal
Storage
CAUTION! Material damage.
▶ Do not subject the appliance to adverse weather conditions or temperatures below freezing.
1. Clean the appliance
2. Store the appliance in a dry, frost-proof place.
Disposal
An appliance that can no longer be used should not be disposed of as a unit, but rather disassembled into
individual parts according to the type of material and then recycled.
WARNING! Danger of cutting injuries. Eye injuries due to splinters of flying glass
Shattering the glass panes of the aquarium and filter basin can lead to eye injuries caused by splinters
of flying glass, as well as cutting injuries.
▶ To dispose of the glass planes with the household waste, do not shatter them.
Possible cause
Mains plug of mains socket not
connected
LED light defective
Mains plug of mains socket not
connected
Feed pump defective
Water quantity in filter basin too low ▶ Refill water in the filter basin
Inflow incorrectly set
Mains plug of mains socket not
connected
Batteries missing/empty
22
Remedy
▶ Insert the mains plug in the mains
socket
▶ Replace the LED light
▶ Insert the mains plug in the mains
socket
▶ Replace the feed pump
▶ Correctly adjust the valve of the
drain pipe g (⌦G).
▶ Insert the mains plug in the mains
socket
▶ Insert/replace batteries