Fault
Fault
code
F13
Fume sensor fault
F14
Delivery sensor 2 fault
F15
Fan fault
F34
Supply voltage under 170V
F35
Irregular mains frequency
Incorrect system water
F37
pressure
F39
External probe fault
A41
Sensor positioning
F42
Heating sensor fault
No communication
A62
between electronic control-
ler and gas valve
EN
Possible cause
Sensor damaged
Wiring shorted
Wiring disconnected
Sensor damaged
Wiring shorted
Wiring disconnected
No 230V power supply
Tachometric signal interrupted
Fan damaged
Electric mains trouble
Electric mains trouble
Pressure too low
Water pressure switch not con-
nected or damaged
Probe damaged or wiring
shorted
Probe disconnected after acti-
vating the sliding temperature
Delivery sensor disconnected
from the pipe
Sensor damaged
Controller not connected
Damaged valve
cod. 3540H322 - 09/2008 (Rev. 01)
Cure
Check the wiring or replace the sensor
Check the wiring or replace the sensor
Check the 3-pole connector wiring
Check the 5-pole connector wiring
Check the fan
Check the electrical system
Check the electrical system
Fill the system
Check the sensor
Check the wiring or replace the sensor
Reconnect the external probe or disable the sliding
temperature
Check the correct positioning and operation of the
heating sensor
Replace the sensor
Connect the controller to the gas valve
Change the valve