5. INSTALLATION POSITIONS

6. INSTALLATION EXAMPLES

1)
2)
3)
4)
5)
6)
G
4
38
Install only indoors.
Install the heat pump boiler securely on a floor surface which can bear the
weight of the heat pump boiler > 300 kg, including water and mounting
materials. When installed on an insufficiently strong floor surface, the heat
pump boiler could fall or the floor can break, causing injury and property
damage.
The heat pump boiler must be installed only in upright position with the air
inlet and air outlet at the top.
Basic installation, using outdoor air and returning used air back to outdoors.
Using energy contained in the indoor air.
Using the heat pump boiler as a boiler as well as to cool an other room.
Using outdoor air and blowing the cold air into the same room as where the
heat pump boiler is placed. The cooled air functions as an air conditioner and
maintains the heatpump hot water function.
Using the heat pump boiler as boiler and dehumidifier (cooled air can contain
less moisture).
Using a space with a large amount of waste heat (in this case for example
because the sun is burning very heavily on the roof).
The higher the air inlet temperature the more efficient the heat pump
boiler will work (max. air inlet temperature 43°C).
Bear in mind: the air outlet temperature is always lower than the air
inlet temperature.
6
5
Illustration 5