Electric heater only.
1. Switch to stand-by mode.
2. Press the
button, the Electrical heating icon
The water is heated by the electric heater only to the temperature set by
parameter "2".
Heating the water in "turbo" mode.
1. Switch to stand-by mode.
2. Press the
button the Heating icon
3. Press the
button, the electrical heating icon
The heat pump boiler is now in 'turbo' mode and will heat the water to the
set temperature parameter "2".
• When pressing the
stand-by mode.
• When pressing the
mode, without the electric heater operating.
NOTE:
1)
The turbo function is used to heat the water to the default value in a shorter
time.
In 'turbo" mode both the heat pump and the electric heater are operating.
When the water temperature reaches 55°C, the heat pump stops to protect
the compressor, now only the electric heater heats the water to the heat
pump boiler water setting temperature.
Heating the water to temperatures of 55°C or higher (max. 70°C).
1. Switch to stand-by mode. Set parameter "0" to the desired water
temperature. ( max. 70°C )
2. Press the
button. The Heating icon
The heat pump boiler will now heat the water to the desired set temperature.
• When pressing the
stand-by mode.
NOTE:
2)
The heat pump stops running at 55°C to protect the compressor. If water is
needed at temperatures higher than 55°C an electric heater will heat the
water from 55°C to the desired temperature. (Parameter "0")
Heating the water at low inlet air temperatures (≤-5ºC)
The heat pump stops functioning at an air inlet temperature of -5ºC and will
start again when the air inlet temperature increases to -3ºC.
How to set the TAW 200 boiler at low inlet temperatures (≤-5ºC):
1. Switch to standby mode. Set parameter "0" to the desired water
temperature (max. 70ºC).
2. Press the
button. The heating icon
is also shown on the screen.
button the heat pump boiler will return to the
button the heat pump boiler stays in running
is shown on the display.
button the heat pump boiler will return to the
is shown on the display.
is show on the display.
is shown on the display.
4
47