Télécharger Imprimer la page

SDMO AT206 Manuel D'utilisation page 59

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
6.6 – DESCRIPTION OF ADVANCED PARAMETERS AND MENUS
Advanced parameters
Setup
Description
Set 1
Nominal
Generator nominal frequency
P1.01
Current transformer ratio
P1.02
Grid choice
P1.03
Set 2
Starting
Choice of 500 rpm signal (Batt charger alt
P2.01
or gen)
P2.02
Engine running alternator voltage threshold
P2.03
Engine running generator voltage threshold
P2.04
Starting by grid fault
P2.05
Glow plug preheating period
P2.06
Starting number
P2.07
Duration of starting
P2.08
Interval between starts
Alarm intervention delay (oil/V/F)
P2.10
Air time duration
P2.11
Air deactivation threshold
P2.12
Set 3
Shutdown
Stop time
P3.01
Decelerated operation period
P3.02
Cooling time
P3.03
Range
50 Hz = 0
60 Hz = 1
2000 = 10000/5
1...2000
0=220SP 1=220TP 2=380TP
0=gen 1=altmm 2=altes
3-30V
20-500V
on = 1
off = 0
1-60 seconds
between 1 and 10
1-30 seconds
1-20 seconds
1-60 seconds
0-10 seconds
30-200 V
1-30 seconds
1-60 seconds
1-300 seconds
SH6000 - SH10000
Single phase
Three-phase
Factory parameter
0
0
20
20
0
2
0
0
10
10
50
50
1
1
10
10
5
5
8
8
2
2
15
15
5
5
30
30
6
6
60
60
30
30
25 / 32
SD6000
Single phase
Three-phase
0
0
20
20
0
2
0
0
10
10
50
50
1
1
10
10
5
5
5
5
2
2
15
15
5
5
30
30
6
6
60
60
30
30

Publicité