Bosch GLL 3 X Professional Notice Originale page 9

Masquer les pouces Voir aussi pour GLL 3 X Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
OBJ_BUCH-1772-005.book Page 9 Wednesday, August 31, 2016 2:31 PM
A
d
– Without changing the height, turn around the measuring
tool by 180°. Direct it against the wall A in such a manner
that the vertical laser line runs through the already marked
point I. Allow the measuring tool to level in and mark the
cross point of the laser lines on the wall A (point III).
– The difference d of both marked points I and III on wall A
indicates the actual height deviation of the measuring tool.
On the measuring distance of 2 x 5 m = 10 m, the maximum
allowable deviation is:
10 m x ±0.5 mm/m = ±5 mm.
Thus, the difference d between points I and III must not
exceed 5 mm (max.).
Checking the Levelling Accuracy of the Horizontal Line
For the check, a free surface of approx. 5 x 5 metres is
required.
– Set up the measuring tool on a firm, level surface between
both walls A and B. Allow the measuring tool to level in
while in horizontal operation with automatic levelling.
A
– At a distance of 2.5 metres from the measuring tool, mark
the centre of the laser line (point I on wall A and point II on
wall B) on both walls.
Bosch Power Tools
A
B
180˚
– Set up the measuring tool 5 metres away turned by 180°
and allow it to level in.
– Align the height of the measuring tool (using a tripod or by
underlaying, if required) in such a manner that the centre
of the laser line is projected exactly against the previously
marked point II on wall B.
– Mark the centre of the laser line as point III (vertically
above or below point I) on the wall A.
– The difference d of both marked points I and III on wall A
indicates the actual deviation of the measuring tool from
the level plane.
On the measuring distance of 2 x 5 m = 10 m, the maximum
allowable deviation is:
10 m x ±0.5 mm/m = ±5 mm.
Thus, the difference d between points I and III must not
exceed 5 mm (max.).
Checking the Levelling Accuracy of the Vertical Lines
For this check, a door opening is required with at least 2.5 m
of space (on a firm surface) to each side of the door.
– Position the measuring tool on a firm, level surface (not on
a tripod) 2.5 m away from the door opening. Allow the
measuring tool to level in while in cross-line operation
mode with automatic levelling, and direct the frontal verti-
cal laser line against the door opening.
B
– Mark the centre of the vertical laser line at the floor of the
door opening (point I), at a distance of 5 m beyond the
English | 9
B
1 609 92A 30A | (31.8.16)

Publicité

Table des Matières
loading

Table des Matières