Abicor Binzel xFUME FLEX Mode D'emploi page 13

Dispositif d'aspiration de gaz de combustion à vide faible
Masquer les pouces Voir aussi pour xFUME FLEX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

xFUME™ FLEX
6 Commissioning
Fold the rubber sleeve down halfway, so that the
8
metal flange is protruding at the top.
Feed the extraction hood's electric cable through
9
the connecting tube from the bottom.
Insert the extraction hood into the connecting tube
10
and rotate it once to secure it in place.
Place the clamp over the metal flange and attach
11
it loosely.
Slide the connector over the profile tube until the
12
screw holes are aligned and then secure the
connector to the profile tube using the screw. The
electric cable must be protruding out of the metal
flange.
Connect the electric cable on the profile tube with
13
the electric cable of the extraction hood. Connect
the corresponding cable colors. The black cables
are labeled with the numbers 1 and 2. Connect
the cables with the number 1 and connect the
cables with the number 2.
Use a cable tie to secure the connected cables on
14
the profile tube.
Trim any protruding ends of the cable tie.
15
Pull the extraction hose over the profile tube until
16
it is over the metal flange.
EN - 13