Faults And Troubleshooting - Abicor Binzel xFUME FLEX Mode D'emploi

Dispositif d'aspiration de gaz de combustion à vide faible
Masquer les pouces Voir aussi pour xFUME FLEX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10 Faults and troubleshooting

10 Faults and troubleshooting
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► The provided filtration system must be used when operating the device.
► Do not open the service door until at least one minute has passed since the device was switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
or a damp cloth.
► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Extraction volume too low.
External extraction system
does not start.
EN - 22
WARNING
Cause
Filter elements saturated.
Extraction arm is blocked.
Close the extraction hood valve.
The power supply is faulty.
Electrical components defective.
Motor protective switch defective.
Remove the extraction hose in the direction shown
7
and replace it with a new one.
 6.1 Mounting the extraction arm on page EN-11
Step 5 and Step 6
 6.1 Mounting the extraction arm on page EN-11
Step 12 to Step 18
Troubleshooting
► Replace the filter elements.
 9.2 Replacing the pre-filter on
page EN-19
 9.3 Replacing the primary filter on
page EN-20
► Remove the blockage from the extraction
arm.
 6.1 Mounting the extraction arm on
page EN-11
► Bring the extraction hood lever into the
vertical position to open the valve.
 6.3 Controlling the volume flow on
page EN-15
► Check the electrical connection.
► Check the cable for damage and replace
as needed or contact customer service.
► Check and replace as needed, or contact
customer service.