Slope - THEIS VISION 2N AUTOSLOPE Instructions De Service

Masquer les pouces Voir aussi pour VISION 2N AUTOSLOPE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Slope

Alignment of the tripod head as to be as accurate as
possible, to guarantee an easier targeting and to use
the complete slope range of the laser of ±15% in both
axes.
The AUTOSLOPE function monitors the slope and
carries out adjustment automatically if necessary.
To do this, first use the sighting telescope or the optical
sight to align the laser exactly to the target point and
then enter the slope settings as follows:
1st key press: Slope is activated. The stored slope
settings of the last use are displayed and and the
automatically approached.
2nd key press: X, slope symbol and one digit flashes
on the display.
Use the arrow keys to set the slope. The blinking digit
can be changed.
To select the digits you must press the counterclock-
wise/clockwise rotation keys. For changing the sign
use the ± button. Plus is not displayed.
When you press and hold the arrow - keys the values
in the display will start to increase slowly and speed up
than.
Pressing both arrow keys at the same time resets the
respective display to 0.
3rd key press: Y flashes on the display.
You can now use the arrow keys to set the slope of the
Y axis in the same way as for the X axis.
4th key press: Confirms your input
After this, the device first starts levelling again, which is
shown by the flashing levelling display. After this, the
entered slope settings are approached.
During this procedure, the slope symbol blinks.
28