NOTES ON TROUBLESHOOTING

Defect
Motor does not run
Tool loses oil
Tool does not reach
final pressure
Battery does not charge
If the defects cannot be remedied, send the tool to the REHAU service center or your dealer!
Cause
- Tool/Battery contacts dirty
- Tool/Battery contacts damaged
- Battery not correctly locked into the tool
- Battery empty
- Battery faulty
- Tool faulty
- Leak in oil tank or release valve
- Leak in oil tank or release valve
- Air in the hydraulic system
- Tool faulty
- Charger not plugged in correctly
- No power coming to socket
- Charger / Mains cable or plug damaged
- Charger not ready
- Charger/Battery contacts dirty
- Charger/Battery contacts damaged
- Battery not locked correctly into the charger
Correction
- Clean contacts when dry with non-conducting material
- Send tool/battery to REHAU service center
- Reinsert battery, pay attention to locking mechanism!
- Charge battery
- Send battery to REHAU service center or independently
give it to the recycling system
- Send tool to REHAU service center
- Do not open the tool and do not remove or damage
the tool seal!
- Send tool to REHAU service center
- Do not open the tool and do not remove or damage
the tool seal!
- Send tool to REHAU service center
- Interrupt the compression process.
- Hold reset knob under tension (see page 8/Item No. 2) and at the
same time continuously actuate the operating switch for about 10
seconds. If this does not correct the defect, the tool must be sent to
a REHAU service center.
- Send tool to REHAU service center.
- Reinsert mains plug
- Change socket
- Send charger to REHAU service center
- Wait for green LED to flash
- Clean contacts when dry with non-conducting material
- Send charger/battery to REHAU service center
- Reinsert battery, pay attention to locking mechanism!