CAM360AHD
9.4
Calibrating the 360° view
!
WARNING! Danger of personal injury by vehicle
• Ensure that all areas around the vehicle are displayed by the system.
Blind spots represent a safety hazard.
• Blind spots can occur when the calibration mats were placed too far
away from the vehicle. This particularly applies to front and rear.
I
NOTE
• When positioning the calibration mats, avoid reflective surfaces or
strong shadows.
• It may be necessary to cover reflective surfaces such as the front pane
with a cloth.
The following materials are required to calibrate the camera angles:
• Calibration set (refer to chapter "Accessories" on page 17):
– 4 calibration mats with calibration pattern (2.0 x 1.6 m)
– or 2 calibration mats with calibration pattern (1.2 x 5.4 m)
• 5 measuring tapes with a minimum length of 10 m
• Adhesive tape
• Optional: Straight beam, rail or board
Key to fig. l, page 10 and fig. m, page 11
No. in
fig. l, page 10 and
fig. m, page 11
L
W
O
➤ Optional: Position the beam, rail or board in front of the back wheels to act as a
limit stop for positioning the side calibrating mats (fig. n, page 11).
➤ Position the calibration mats as shown in fig. l, page 10 (4 calibration mats) or
fig. m, page 11 (2 calibration mats) and secure them with adhesive tape.
– The calibration mats must be entirely visible.
➤ Position the measure tapes as shown in fig. l, page 10.
– Form a rectangular shape around the vehicle.
EN
Description of the dimensions
(Do not apply the vehicle dimensions.)
Distance to the front and rear calibration mats
Distance to the left and right calibration mats
Offset between front calibration mat and side calibrating mats
(must be identical on both sides)
Video system settings