LEDs
LED flashing modes:
Parameter
Set value /
ventilation level
Power units
0
(LT) or
1
room air
2
controls
3
(LLS)
4
5
6
230 V AC
1
input
2
3
4
5
6
Sensors
0
1
2
3
4
5
6
7
LED flashing rapidly
10 Commissioning | UK
Setting /
description
Operation without further LT/LDS
Operation with 1 LT or LDS
Operation with 2 LT or LDS
Operation with 3 LT or LDS
Slave no. 1
Slave no. 2
Slave no. 3
Adjuster for adding further room air
controls (LDS) or power units (LTs) to
this room air control. Example: Two
further LDS (LDS #2 and #3) are con-
nected to LDS #1. Set value = 2. Set
set value 4 on LDS #2 and set value 5
on LDS #3.
Notice: Only single-type LDS combi-
nations are permitted!
Sleep mode
Intermittent ventilation
Safety shutdown
Supply air operation without overrun
Supply air operation with overrun time
of 6 min.
Supply air operation with overrun time
of 15 min.
For setting an additional function.
This can be activated with a button
or switch at the 230 V input.
No sensor
1 internal sensor
1 internal sensor + 1 external sensor
1 internal sensor + 2 external sensors
1 internal sensor + 3 external sensors
0 internal sensors + 1 external sensor
0 internal sensors + 2 external sensors
0 internal sensors + 3 external sensors
Select how many internal and external
sensors are connected/combined.
The LD 45 HYI internal sensor and
the LD 45 HY, LD 45 CO2 and LD 45
VOC external sensors are available.