Connecting Room Air Controls - AIT LD 30 BO Notice De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
!
Danger of electric shock from installing
the LDS 45 O and LDS 45 K inside the pro-
tective zone. No IP protection present
(IP 00). The room air control may only be
installed outside protective zones 0, 1 or 2.
When wiring several ventilation units,
i
always use a deep/double recessed-
mounted box (recessed-mounted box
provided by customer).
Strip wires of connection cables suffi-
i
ciently.
9.7 Connecting room air controls
LDS 45 O and LDS 45 K controls
i
with 230 V. Note safety requirements
in Chapter 9.6.
Wired systems
An LDS 45 O or LDS 45 K master room air
control can have a maximum of 3 further
power units and/or slave room air controls of
a similar design added to it.
A maximum of 4 control units can therefore be
deployed in this ventilation system.
You can only combine room air con-
i
trols of the same type (either LDS 45 O
or LDS 45 K).
The LDS 45 K controls and all other room air
controls/power units are connected via the
RS 485 interface.
If further room air controls are connect-
i
ed, these must be defined as slaves in
service mode  Operating instructions
or commissioning instructions.
The relevant ventilation units are connected to
the relevant room air controls. The ventilation
units on an LDS 45 O/K are generally con-
nected directly to the Fan1 and Fan2 terminal
block.
Radio-controlled systems with LD 45 K
control and LD 45 EO-ER radio module
External radio sensors and LD 45 RC units
can be connected to the LD 30 BK with these
unit combinations.
Connections
For possible combinations  Chapter 7.
To install the room air control, we always
recommend using a deep recessed-mounted
box. If connecting more than 2 units, we
recommend wiring in another recessed-
mounted box.
LD 30 ventilation units are not suitable
i
for use with LD 45 LT power units.
Connecting LDS 45 O
LDS 45 O room air control is used to activate
LD 30 BO units.
1. Take off frame of room air control.
2. Connect the LDs according to the wiring
diagram ( Appendix).
The exhaust air function is only possi-
i
ble if a LD 30 BO is connected (service
mode setting for unit type = LD 30 BO
and number of units = 1).
3. Insert room air control in the re-
cessed-mounted box and screw down to
recessed-mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening
is above the LD 45 HYI (if fitted) and that
the frame engages.
5. Start up ventilation system  Chapter 10.
Connecting LDS 45 K
9 Mounting | UK
35