Risk of death from carbon monoxide
when operating with air-ventilated
fireplaces. Ensure sufficient supply air intake
during operation with air-ventilated fireplaces.
Note maximum permissible pressure diffe-
rence per residential unit. The consent of a
professional chimney sweep is needed in all
cases.
Ventilation units may only be installed in
rooms, apartments or housing units of a com-
parable size, in which air-ventilated fireplaces
are installed if:
● a parallel operation of air-ventilated fire-
places for liquid or gaseous fuels and the
air-extracting equipment can be prevented
via safety devices, or
● the extraction of exhaust gas from the
air-ventilated fireplaces is monitored by
special safety equipment. In the case of
air-ventilated fireplaces for liquid or gaseous
fuels, the fireplace or the ventilation system
must be switched off if the safety device is
triggered. In the case of air-ventilated fire-
places for solid fuels, the ventilation system
must be switched off if the safety device is
triggered.
Exercise caution when handling
packaging materials.
 Observe applicable safety and accident
prevention requirements.
 Store packaging material out of the reach
of children (risk of suffocation).
5 Requirements of the installation
site
● Ambient temperature - 15 °C to + 40 °C.
● Airstream temperature max. 40 °C.
● Max. permissible humidity in installation
room 90 % (at 20 °C).
● A level and solid wall surface is needed for
wall installations.
● For filter changes, ensure sufficient space
to work in front of the unit.
5 Requirements of the installation site | UK
● Do not drill core drill hole for unit assembly
and do not drill fixing points on external and
internal covers in load-bearing components,
such as in the lintel or ring beam.

6 Technical data

External diameter
Wall thickness
Wall sleeve
(max. length)
Air filter
Air volume/unit
Degree of protection
Sound pressure level,
at distance of 1 m
conditions without
obstructions (ventilation
level 1 to 5)
Rated voltage/
power frequency
Volumetric flow
heat recovery mode
ventilation level 1 to 5
Volumetric flow, exhaust
air mode (no heat
recovery)
Power consumption
(ventilation level 1 to 5)
Degree of heat provision 72 - 73 % (level 3)
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight slide-in module
cpl.
DN 160
320 - 790 mm
LD 45 RH 500: 500 mm
LD 45 RH 800: 800 mm
G3/G3
42 m³/h
IP X4
18 / 32 / 41 /
45 / 49 dB(A)
230 V
50/60 Hz
5 / 12 / 18 /
22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
0.19 W / (m³/h)
A (-39.41)
From star point max.
25 m per ventilation unit
3.6 kg
27