TROUBLESHOOTING
Problem
Unable to pull back rod
Unable to push rod forward
No grease when trigger is pulled
Grease appears in relief valve
Motor does not run when trigger
is pulled
Grease leaks out of the back of
the grease tube
Possible Cause
Vacuum build up
Pressure build up
Rod is still connected to plunger
Grease tube is empty
Air pockets in the grease tube
Check valve is clogged
Filter is clogged
Zerk fitting is blocked
Battery
Rubber seal is flipped the wrong direction
Possible Solution
Unscrew the purge valve to release vacuum.
Unscrew the purge valve to release pressure.
Rotate grease tube handle 90 degrees to disengage it.
Add grease.
Refer to Purging Air Pockets.
Refer to Cleaning Contamination from the Check
Valve.
Refer to Cleaning Contamination from the Filter.
Disconnect coupler from fitting, clean zerk fitting and
grease path.
Make sure the battery is fully charged.
Refer to Preparing the Grease Gun for Suction and
Filler Pump Filling.