10.3 Connect the electric T-junction (c) (see
10.4 Close up the damp-room junction box with the protective cap.

11. Installing the Electric T-junction

Important!
The components of the electric T-junction must be installed only when they are in a
dead condition.
Recommended system cables see
When using other cables for the system cable, note the different colour coding. The
outer diameter must not exceed 7.5 mm.
11.1 Strip the shielding (a) off from the system cables (approx. 40 mm).
11.2 Place the union nut (c) on the system cable (b) up to the stop.
The cable cores are marked with numbers 1 through 4.
11.3 Latch the cable cores (d) into the cable core guides (e) according to their colours.
A: Union nut
B: FAR-Order-No. 2000104272
FAR-Order-No. 2000104274
FAR-Order-No. 2000100801
FAR-Order-No. 2000100852
11.4 Cut off the protruding ends of the cable core so that they are flush, i. e. so that they
do not protrude.
11.5 Place the union nut (c) on the electric T-junction (f) and tighten with the required
torque (1.2 Nm).
Caution!
Ensure correct polarity.
Each core cable colour must be in the same cable core guide on both union nuts.
When the union nut is being tightened, an electric contact and the pull-relief are
automatically established.
Special seals provide protection against dust and water.
Chapter
11.).
Chapter
10., Accessories.
1
2
3
4
A
B
brown
red
white
white
blue
blue
black
black
7