12. Assembly Instructions

Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
Important!
• Before installing, flush the pipes in compliance with DIN 1988.
• Do not shorten the connector hoses located at the fitting.
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections.
12.1 Install the fitting (a) on the washbasin (b).
The corner valves (c) must be provided by the customer.
12.2 Screw the connecting hose (d) on to the corner valve.
12.3 Install the line connection between the fitting and the electric T-junction.

13. Function

13.1 Allow your hand to approach the sensor.
• Water flows.
13.2 Remove your hand from the sensor.
• Water flow stops automatically.
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections.
The range of the sensor can be set with the system software.
"Hygiene Flushing" function
Caution!
When the "Hygiene Flushing" function is used, it must be ensured that the water can
flow away properly.
• The "Hygiene Flushing" function ensures that forced flushing takes place to
exchange the water in the branch lines after 24 hours of non-use.
• The "Hygiene Flushing" function can be switched on and off with the system
software or directly on the fitting.
• This function is switched on at the factory.