2. Configuring the intercom (see fig. 1, fig. 2 or fig. 3)
a. Configuring the intercom number:
Place switch 2 on the left on intercom no. 1 and on the right on intercom no. 2.
b. Configuring the number of families:
Place switch 1 on the left to be in one-family mode and on the right to be in two-family
mode.
c. Intercom volume settings:
Turn the volume control with a Phillips head screwdriver to adjust the intercom volume.
d. Configuring the RFID function:
1) Programming (or resetting) the administrator badges:
When switching on the device for the first time, the badges must be configured in the
following order:
1. Press the reset button at the back of the intercom panel for five seconds, the intercom
panel will emit six short beeps.
2. Swipe the yellow administrator badge, one short beep confirms the programming.
3. Swipe the blue badge, one short beep confirms the programming.
4. Swipe the red badge, one long beep confirms that the administration badges have been
programmed.
2) Add one or more user badges:
1. Swipe the blue badge, four long beeps confirm the activation of the programming mode.
2. Swipe all user badges (grey) to be activated; one short beep confirms the programming
of every badge presented.
3. Once all of the badges have been programmed, wait 10 seconds. One long beep confirms
the end of the programming process.
3) Remove one or more user badges:
1. Swipe the badge (red); 4 long beeps confirm the activation of the programming mode.
2. Swipe all user badges (grey) to be deactivated; one short beep confirms the deactivation
of every badge presented.
3. Once all badges have been deactivated, wait 10 seconds. One long beep confirms the
end of the programming process.
4) Remove all user badges:
1.
Swipe the administrator badge (blue); 4 short beeps confirm the activation of the
administration mode.
2. Swipe 1 user badge (grey) that has already been added; one short beep indicates that all
user badges have been deactivated.
5) Using the badges:
To open the electric strike plate, quickly swipe your pre-programmed grey user badge on
the RFID reading field. One short beep confirms the opening of the electric strike plate.
To open the gate motor, hold the badge in front of the RFID scan area for 3 seconds. Two
short beeps confirm the opening of the gate.