CoolAir SP950T
8.3

Menu level 2: Low voltage cut-off

The battery monitor protects the battery from excessive discharging.
A
NOTICE!
When the battery monitor switches the device off, the battery only has part
of its charging capacity. Avoid starting repeatedly or operating electrical
consumers. Make sure that the battery is recharged. As soon as the required
voltage is available again, the unit can be operated again.
If only the set power supply is available here for the air conditioning roof unit, the
unit is switched off.
➤ Start configuration mode (chapter "Starting and ending configuration mode"
on page 23).
✓ The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
➤ Press the + button once to switch to menu level 2.
➤ Press the
✓ The digits in the display flash until the parameter you entered is confirmed.
➤ Use the + and – buttons to set the value for low voltage shutdown. The
characteristic figures at second and third place on the display represent the
voltage (V) at which the unit is shut down:
Characteristic
figure
➤ Press the
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 2 again and can use the + and – buttons to switch
between menu levels.
EN
button to change the parameter.
Low voltage
shutdown
1
22.2
2
22.4
3
22.6
4
22.8
5
22.9
button to confirm your entry.
Configuration of unit software
Characteristic
Low voltage
figure
shutdown
6
7
8
9
10
23.0
23.1
23.2
23.4
23.6