DESCRIPTION
The macerating system of this unit is installed in
a case, specifically designed for horizontal outlet
spigots. This macerator manufactured in a factory
which is quality certified to ISO 9001(2000)
accredited by AFAQ. Correct operation of your
init depends on correct installation and usage.
Please pay particular attention to the following:
"
"
Possible danger to personnel,
"
"
Warning of possible electrical hazard,
"WARNING"
This is a general warning that
failure to follow instructions could result
in poor functioning of the unit.
2
LIST OF ACCESSORIES
See fig. n°
.
INCLUDED:
2
3
DIMENSIONS AND OVERALL
See fig. n°
.
MEASUREMENTS:
3
4
TECHNICAL DATA:
This pump/macerator has been designed to
pump away the waste from a WC and the
sanitary appliances mentioned in fig n°
This unit is for domestic use only.
Installed and used correctly, this unit will give
consistent and reliable service.
You can find the technical data in fig n°
Application
1 WC + Washbasin
Type
+ Shower + bidet
Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 1,8 A
Electric Class
Degree of protection
Net Weight
Only installations conforming to the
above specifications are acceptable.
WARNING:
5
See fig. n°
.
PERFORMANCE CURVE:
5
6
HEIGHT AND LENGTH
The possible combinations of height and length
OF THE DISCHARGE PIPE:
of the discharge pipe are shown in fig.
7
INSTALLATION
The unit must be connected to WC
pan with a horizontal otlet spigot conforming to
WARNING:
EN33 or EN 37.
The macerator and its connections is integral
with the WC pan itself.
The unit should be accessible for possible
service.
It is supplied with fixing lugs to prevent it from
moving during use.
7a
WC CONNECTION
• First, put some silicon or liquid soap on the
WC spigot
• Fit the collar supplied on the bowl outlet
• Pull the flexible sleeve over the pan spigot
• Position the jubilee clip over the edge of the
flexible sleeve, and tighten with a
screwdriver
• Once the appliance has been positioned, fix
it to the floor using the 2 screws supplied.
WARNING !!!
There should be no dripping of water from the
WC cistern or any other sanitary appliances.
If there is, this will cause the unit to activate
repeatedly as it pumps the water away.
7b
CONNECTION OF EXTRA SANITARY
APPLIANCES
See fig. n°
for such connections as may be required for
sanitary appliances.
to the unit that the underside of the shower tray
WARNING:
is raised by at least 15 cm from the floor.
7c
CONNECTION OF DISCHARGE
(cf. technical data sheet fig.
PIPEWORK
• Use the elbow
• Insert the sleeve on the elbow. Fix it in place
.
with a metal hose clip
1
• Orient the assembly as required and lock it in
place in the orifice in the cover (hose clip
• Cut off the end of the sleeve, if necessary, to
suit the diameter of the discharge pipe, and
.
use a collar
8
ON01-K70
2,5 m
7d
TECHNICAL ADVICE FOR DISCHARGE
220-240 V
(cf. technical data sheet fig.
PIPEWORK
50 Hz
• Horizontal pipe runs must have a minimum
400 W
fall of 1:100 (10 mm per metre) to the soil
stack,
IP44
I
• If a vertical lift is required, it must be made
5,8 KG
before the horizontal run at the start of the
piperun,
• We would recommend that a drain-off point
is installed to allow the discharge pipework
to be drained down before any service work,
• If the discharge pipework runs to a level
considerably lower than the unit, the resultant
syphoning effect can suck out the water seal
in the unit. Fitting an air admittance valve
capable of taking around 10 psi pressure
(BBA approved) at the high point of the pipe
run will overcome this problem,
.
• The discharge pipework must be connected
6
to the soil stack using an appropriate strap
on boss,
• Ensure all external pipework is adequately
lagged to avoid the possibility of freezing.
Any elbow on the discharge pipe of the
unit will create friction loss (roughly 50 cm per
N.B. :
elbow to be deducted from the vertical
pumping spec.)
et fig. n°
1
2
3
7b
,
7b
7b
Ensure when connecting a shower
).
7c
and the stepped sleeve
A
.
B
B
or
.
D
H
).
7d
Use smooth pulled bends for
discharge pipework, or 2x45° bends inseries.
WARNING :
do not use 90° elbows.
We advise to install an external alarm system
"SANIALARM", which warns the user in case of
electrical power failure or unit malfunction. The
drilling position is marked on the cover.
7e
CONNECTION TO THE ELECTRICAL
SUPPLY
The electrical installation should be
carried by a qualified person.
The unit should be connected to a fully earthed
electrical supply. All wiring must conform to
BS7671, 1992 requirements for electrical
installations. The unit requires a 220/240V
single phase AC 50 Hz supply (UK specification).
Do not connect the unit to a conventional plug
and socket. It must be wired into a fused,
unswitched, fixed wiring connector fitted with a
5 amp fuse. The wires in the mains lead are
coloured in accordance with the following
code:
Brown - Live
Blue - Neutral
Green/Yellow - Earth
Warning: Ensure the electricity is turned OFF
at the main switch board before wiring to
connector.
All work on cable, pressure chamber and
motor should only be carried out by a qualified
Saniflo servicing agent, as special tools are
required.
.
C
8
NORME
• This appliance conforms to EN 12050-3.
).
Lifting plant for wastewater containing faecal
matter for limited applications and the
European directives and standards
concerning electrical safety and
electromagnetic compatibility.
9
COMMISSIONING THE UNIT
To check that all connections are watertight, run
the WC, shower, washbasin, one after the other
for a few minutes to represent normal usage.
Ensure there are no leaks.
Once all electrical and plumbing connections
have been checked, flush the WC.
The motor of SANISLIM
more than 5 to 10 seconds, depending on the
height and length of the discharge pipework. It
may run in several shorter bursts. If it runs for
more than 20 seconds, check that the discharge
pipe is not kinked or blocked.
WARNING: There should be no dripping of
water from the WC cistern or taps. Otherwise,
this will cause the unit to activate repeatedly as
it pumps the water away.
should operate for no
®

Publicité