61000-4-8, IEC 61000-4-11) and is subject to particular pre-
cautions with regard to electromagnetic compatibility. Please
note that portable and mobile HF communication systems
may interfere with this unit.
• This device corresponds to the EU Medical Devices Direc-
tive 93/42/EEC, the German Medical Devices Act (Medizin-
produktgesetz) and the standards EN 1060-1 (non-invasive
sphygmomanometers, Part 1: General requirements),
EN 1060-3 (non-invasive sphygmomanometers, Part 3:
Supplementary requirements for electro-mechanical blood
pressure measuring systems) and IEC 80601-2-30 (Medical
electrical equipment – Part 2 – 30: Particular requirements
for the basic safety and essential performance of automated
non-invasive sphygmomanometers).
• The accuracy of this blood pressure monitor has been care-
fully checked and developed with regard to a long useful
life. If using the device for commercial medical purposes, it
must be regularly tested for accuracy by appropriate means.
Precise instructions for checking accuracy may be requested
from the service address.
• We hereby confirm that this product complies with the
European RED Directive 2014/53/EU. The CE Declaration of
Conformity for this product can be found under: www.beurer.
com/web/we-landingpages/de/cedeclarationofconformity.
php.

13. Mains part

Model No.
OH-1048A0500600U2 VDE
Input
100 – 240 V AC, 50 – 60 Hz; 120-60 mA
Output
5 V DC, 600 mA, in conjunction with Beurer
blood pressure monitors only
Manufac-
Dongguan Oriental Hero Ele. Co., LTD.
turer
Protection
The device is double protected and has a
primary-side cutout switch which discon-
nects the device from the mains in case of
malfunction.
Polarity of the the DC voltage connection
Insulated / protection class 2
Housing and
The housing of the mains part protects users
protective
from touching live parts or parts that could be
covers
live (for example with their fingers, or with a
needle or checking hook).
The user must not touch the patient and the
output connector of the AC mains part at the
same time.

14. Replacement parts and wearing parts

Replacement parts and wearing parts are available from the
corresponding listed service address under the stated material
number.