Setting ranges
Temperature:
Humidity:
The maximum humidity level which can be set depends on the temperature of
the sauna. The higher the sauna temperature, the lower the maximum humidity
level which can be set.
Thermal safety
Heater sensor with overheat cut-out (139 °C shut-off temperature)
Adjustable automatic heating period (6 h, 12 h, 18 h, 24 h)*
Optional single-sensor mode or two-sensor mode
Connection cables
Power supply cable:
Heater supply cable (temperature-resistant up to 150 °C):
Sensor leads (temperature-resistant up to 150 °C):
Light lead:
Fan lead:
* EN 60335-2-53 specifies a heating time limitation of 6 h for private saunas.
For saunas in hotels, apartment blocks and similar locations, a maximum heat-
ing period limit of 12 hours is permissible. Extending the heating period limit to
18 hours or 24 hours is only permitted in public saunas.
p. 69/70
30 °C to 110 °C
0% to 100%
min. 5 x 2.5 mm²
min 2.5 mm²
min 0.5 mm²
min. 1.5 mm²
min. 1.5 mm²