Installation instructions, for professionals only

4.4. Installing bench sensor F2 (optional)

The bench sensor must be installed on the wall of the sauna room, above the
rear bench seat. A clearance of approx. 15 cm from the roof of the sauna room
must be maintained.
To install the bench sensor, perform the following steps:
1. Route the two 2-core bench sensor leads in the wall of the sauna room to
the bench sensor installation location and affix the bench sensor leads us-
ing cable clips.
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor lead to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna room using the two wood
screws enclosed (16 mm). Maintain a clearance of 15 cm from the roof of
the sauna room.

4.5. Installing humidity sensor FTS2

(optional, only Pro D3/Pro D3i)

The humidity temperature sensor must be installed on the wall of the sauna
room above the rear bench seat. A distance of approx. 15 cm from the roof of
the sauna must be maintained.
To install the humidity temperature sensor, perform the following steps:
1. Route the two 5-core bench sensor leads in the wall of the sauna room to
the humidity temperature sensor installation location and affix the sensor
leads using cable clips.
2. Install the humidity temperature sensor to the wall of the sauna room using
the two wood screws enclosed (16 mm). Maintain a clearance of 15 cm from
the roof of the sauna room.