Remove the GRAF SILENTIO light mains water back-up supply from its transport packing; in the same
box are also the other parts and accessories. Firstly, check the whole equipment for any possible
damage. Any damage must be reported before the assembly and installation begins.
4.1
Wall assembly
The GRAF SILENTIO light mains water back-up supply must be installed above the back surge level and
in a frost free and dry environment that is above any possible regional flood levels.
When choosing a position for installation it is important to be sure that there is at least 50 cm free space
available above the equipment for any maintenance or adjustment regulation. The wall intended for
mounting must be suitable for supporting the equipment with an approxi-mate maximum weight of 45 kg
when filled with water.
Drinkingwater
connection
The holes to be drilled are marked out on the wall using the template and then drilled with a 10 mm
masonry bit, the holes should be approximately 60 mm deep. Insert the enclosed dowel-plugs and then
screw in the stud bolts so that approximately 8 mm remains protruding. Attach the two rubber buffers with
the inside and outside threads to the two upper studs and attach the two rubber buffers with the double
inside threads to the lower studs.
info@graf.info
4.

Installation and assembly

Bohrbild:
Upper fixing drill
bit 10 mm
Trinkwasser
anschluß
www.graf.info
obere Befestigung,
Bohrer 10 mm
untere Befestigung,
Lower fixing
Bohrer 10 mm
drill bit 10mm
Rubber buffers
20 / 50