Graf SILENTIO Notice D'installation Et D'entretien page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.6
Floating switch connection
The floating switch cable is laid from the underground tank through the empty tube to the Silentio light.
The special double plug is plugged into a 230 V socket. The 3-way valve is connected to this double plug.
The floating switch is to be fixed in the container in such a way that the float head floats approx. 10 – 15
cm above the tank floor in an extended state. The yellow counterweight is to be positioned approx. 20 cm
above the float head.
Counterweight
Float head
Before the commissioning of the system all of the inlet and outlet pipes must be thoroughly rinsed
through. Small foreign objects up to 0.2 mm can cause substantial damage to pumps and other
equipment.
Never run pumps without water in the system!
and the system will be running. If the pump does not run or cuts out after a short time, then press the
reset button on the controlmatic. This procedure is to be repeated until the water emerges without air
bubbles at the outlet which is then closed, the pump will reach it's maximum pressure and stop
automatically.
If it is not possible to fill the suction pipe with this method then it is also possible to fill it at the
SILENTIO light unit, to do this the flow valve of the suction pipe in the tank must be opened. The filling
must continue until the water emerges at the cistern end. The system may now be put into operation as
described above.
Finally the commissioning is competed by opening the mains water supply to the back-up supply tank.
This fills the tank and before the water flows out of the overflow the float valve must close off the inlet. If
this does not happen then the polystyrene float that controls the valve must be adjusted.
info@graf.info
www.graf.info
4.
Installation and assembly
Counterweight
Float head
5.
Commissioning
Remove the threaded fill plug from the pumps' body
and completely fill the housing with water. Then also
fill the suction pipe with water. To do this, the cistern
Filling plug
side end of a pipe is connected to the suction pipe
(remove the basket) and an outlet in the house is
opened. Be sure that the red 3 way valve is set to
automatic [A]. By opening the inlet valve on the
filling hose the complete system is filled with water
until the water emerges free of air bubbles. With this
method the system is reliably bled of air and is now
ready for
connection to the mains plug (230 V / Fused 16 A)
23 / 50
operation.
Now make the electric

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières