Using the cable clips supplied (Fig. 7), attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 8/Item 10).
Please ensure that the ejector fl ap can be opened
and closed easily!
Adjusting the scarifi er depth (see Fig. 9)
The scarifi er depth is adjusted at both front
wheels via the adjustment mechanism. For this,
pull out the adjusting screw and turn the wheel to
the left or right into one of the available positions
(0/I/II/III).
The scarifi er depth must always be identically set
on both sides!
0 = drive/transport position
I = scarifi er depth 3 mm
II = scarifi er depth 7 mm
III = scarifi er depth 9 mm

Electrical connection

The equipment can be connected to any normal
socket with 230V AC. It is only acceptable to con-
nect it to a shockproof socket with a 16A circuit
breaker. Furthermore, a residual-current-operated
protective device with max. 30 mA should be con-
nected upstream.
Power cable
Please only use power cables that are not dama-
ged. The total length of the power cable should
not exceed 50 meters; going beyond this distance
will reduce the power output of the electric motor.
The power cable must have a cross-section of 3 x
1.5 mm2. The insulating sheath of scarifi er power
cables is frequently damaged.
Some of the causes for this are:
Cracking from running over the cable
Pinching when the power cable is dragging
under doors and pulled through windows
Cracking due to old age of the insulation
Kinking by improperly fastening or guiding the
power cable
The power cables must, at the very minimum, be
of type HO5RN-F and 3-stranded. The cable type
must be printed somewhere on the power cable.
Only purchase power cables that are marked as
such! Plugs and socket couplers for the power
cables must be made from rubber and be splash-
proof. There is a limit to how long power cables
can be. Longer power cables require larger con-
ductor cross-sections. Power cables and connec-
Anl_GC_ES_1231_SPK1.indb 17
Anl_GC_ES_1231_SPK1.indb 17
GB
ting lines must be regularly checked for damage.
Ensure that the lines are de-energized before
checking them. Completely unwind the power
cable. Also check power cable entry points, plugs
and socket couplers for kinks.
6. Operation
Connect the machine's power supply cable to the
plug (Fig. 10/Item 1) and secure the power cable
with the stress-relief clip (Fig 10/Item 2).
To prevent accidental start-up of the equipment,
the push-bar (Fig. 11 / Item 5) is equipped with
a safety lock-off (Fig. 11 / Item 2) which must be
pressed before the lever switch (Fig. 11 / Item 1)
can be pressed. If the lever switch is released, the
equipment switches off .
Repeat this process several times so that you are
sure that the machine functions properly. Before
you perform any repair or maintenance work on
the machine, ensure that the cutting unit is not ro-
tating and that the power supply is disconnected.
Important! Never open the ejector fl ap when the
motor is running. A rotating cutting unit can cause
injuries.
Always fasten the ejector fl ap carefully. The fl ap
fl ips back to the "Closed" position by the tension
springs!
Always ensure that a safe distance (provided
by the long handles) is maintained between the
user and the housing. Be especially careful when
scarifying and changing direction on slopes and
inclines. Maintain a solid footing and wear sturdy,
non-slip footwear and long trousers. Always sca-
rify along the incline (not up and down).
For safety reasons, the scarifi er may not be used
to scarify inclines whose gradient exceeds 15
degrees.
Use special caution when backing up and pulling
the scarifi er (tripping hazard)!
Tips for proper working
It is recommended that you overlap scarifying
paths a little.
Try to scarify in straight lines for a nice, clean look.
Insodoing, the aeration swaths should always
overlap each other by a few centimeters in order
to avoid bare strips.