FreshJet3000
• Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
• Ensure that the mains voltage supply has a residual current circuit breaker.
• Make sure that the grounding cable of the air conditioner is connected to the
vehicle's grounding system.
There are two ways of installing the roof air conditioner:
• Making a new opening (chapter "Making a new opening" on page 15). In this
case the opening must be reinforced by an appropriate frame.
• Using an existing opening in the vehicle such as a roof hatch or replacing an
old air conditioner (chapter "Installing in an existing opening" on page 16).
8.2
Making a new opening
See fig. 5, page 4
➤ Select an area at the centre on the roof between two longitudinal supports.
➤ Mark the position and size of the opening (preferably 400 x 400 mm or
optionally 360 x 360 mm).
See fig. 6, page 4
➤ Drill out the corners (A).
➤ Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
➤ Make sure no electrical power cables are damaged.
See fig. 7, page 5
➤ Before installation, check whether the roof hole needs reinforcing.
➤ If needed, remove the foam according to the width of your reinforcing rails
(not in scope of delivery) (A).
➤ Fit the reinforcing rails (B).
➤ If needed, fit a suitable H-frame to provide reinforcement to the roof.