Important Remark - Esmach SPI 160 A hybrid Notice D'utilisation Et De Maintenance

Petrin a spirale a cuve fixe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BOWL-IMPULSES" COMMAND
With the machine at a standstill, not in the work cycle (i.e. at the end of an automatic cycle or
after interrupting a manual cycle by pressing the "stop" key twice) and the bowl protection open,
impulse rotation of the bowl can be commanded by pressing key 13 "bowl inversionimpulses".
MACHINE WITH "INFRA-RED" MEASUREMENT DEVICE
The temperature measurement does not require any direct operation of the operator ( the de-
vice is permanently installed under the head of the machine and executes its function without
interruption). According to the value assigned to parameter P07 the following alternatives are
possible:
P07 = 0 = check the mixture temperature without stopping the cycle; if the temperature value
measured exceeds the value set up, an acoustic alarm is activated through flashing
and the display (17) blinks showing the value of the temperature every 4 seconds.
P07 = 1 = if the temperature value measured exceeds the value set up, this is detected through
the activation of a flashing acoustic alarm; the system controls the stop of the ongo-
ing cycle and the display (17) blinks showing the value of the temperature every 4
seconds. The operator can allow the cycle to proceed by pressing the button START
(15) or cancelling it by pressing the button STOP (16).
P07 = 2 = the value of the temperature measured is displayed only (flashing) without any fur-
ther effect.
IMPORTANT REMARK: the acoustic alarm is activated
temperature measured exceeds the value set up in the program; for later exceedings,
no acoustic alarm is activated.
In MANUAL operating mode, the temperature is shown on the display (17) only and no value can
be set up for it.
HOW TO SET UP THE TEMPERATURE VALUE IN A PROGRAM
For each program ( from 0 to 9) a different temperature value can be set, but in the range be-
tween 0 °C and 65 °C (32 °F and 149 °F). To set and store the temperature value in a program,
proceed as follows:
-press repeatedly the button (9) until the program required is shown on the display (8)
-press the key PROGRAM (9) for about 3 seconds and keep it pressed until the led (10)
switches on and the display (8) starts blinking.
-press again the key (9) ( the display (19) blinks); set the temperature through the keys (3),
(4),(6),(7)
-if the machine has no ingredient dispenser systems, by pressing the key (9) for 3 seconds, it is
possible to go out from PROGRAMMING (the led (10) switches off and the display (8)stops
blinking), and the data are saved; otherwise switch to the programming of the 1° dispenser
If the set up temperature value has been exceeded, this may depend on the following :
a)machine not in operation: the display (17) blinks, showing the value of the temperature every
4 seconds
b)machine in operation: the display (17) blinks, as in case a), and ( only the first time when the
temperature value set exceeds, then no more) the acoustic alarm is activated for a time of 10
seconds.
The warning time is set up through the parameter P05
the first time only when the
English
39

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Spi 200 a hybridSpi 250 a hybridSpi 300 a hybrid

Table des Matières