Parameters
Setting range
Min / Max
Screed
Off
On
Screed Pro-
10 - 70 °C per
gram
heating day
Tab. 7-25 Parameter in menu: "Additional programs"
7.7

Information

[→ Main menu → Information]
7.7.1

Overview

[→ Main menu → Information → Overview]
Parameters
Setting range
Min / Max
Mode
No request
Heating
Cooling
Domestic hot wa-
ter preparation
Defrost
Ext
No external mode Heat pump operates in normal operation.
Low rate
High rate
SGN
SG1
SG2
SG3
RT
Off
Request
No heat request If [Room thermostat] = Yes
IL1
IL2
Pump
Off
On
V
-
EHS
-
TV
-
TVBH
-
TR
-
Tdhw
-
Psyst
-
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
Description
Function for screed drying
Deactivated
The feed target temperature is regulated according to the set [Screed pro-
gram]. The day on which the screed function is activated is not included in
the running time of the screed program. The first day starts when the day
changes at 00:00 am. On the day of activation, heating is carried out for the
remaining time with the feed target temperature of the program of the first
day (see
Chap.
4.5.7).
Setting of the sequence program of the screed heating. An individual feed
target temperature can be set for each day for a maximum duration of 28
days. The end of the screed program is defined by the 1st day with the tar-
get value setting "Off" (see
Chap.
Description
Current mode of the heating pump.
External request:
EVU function HT/NT active and low rate.
EVU function HT/NT active and high rate.
EVU function Smart grid active, normal operation.
EVU function Smart grid active, discharge: No heat pump operation, no
frost protection function.
EVU function Smart grid active, switch-on recommendation, operation at
higher target temperatures, inexpensive electricity.
EVU function Smart grid active, switch-on command and storage tank
charging to 70 °C, inexpensive electricity
Room thermostat/Interlink:
If [Interlink function] = On: frost protection only; otherwise: Off
If [Room thermostat] = Yes
If [Interlink function] = On: Normal feed target temperature
If [Interlink function] = On: In heating mode increased feed target temperat-
ure, in cooling mode reduced feed target temperature
Status of the internal heating circulation pump (On/Off)
Current volume flow in the heating system
Current output of the optional backup heater in kW
Current feed temperature after the plate heat exchanger (tV) in °C
Current feed temperature after heating support (tV, BH) in °C
Current return flow temperature in °C
Current temperature in hot water tank in °C
Current water pressure in the heating network in bar
4.5.7).
7
Parameter settings
Factory
Incre-
Access
setting
ment
BE HF
-
N
See
1 °C
N
Chap.
4.5.7
Factory
Incre-
Access
setting
ment
BE HF
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
Operating Instructions
E
E
S
S
S
S
S
S
S
S
S
S
S
45