Parameter settings
7.3

User

[→ Main menu → User]
7.3.1

Menu: Room temperature target

[→ Main menu → User → Room]
Parameters
Setting range
Min / Max
Room tem-
5 - 40 °C
perature set-
point 1
Room tem-
5 - 40 °C
perature set-
point 2
Room tem-
5 - 40 °C
perature set-
point 3
Tab. 7-6
Parameter in menu: "Room temperature target"
7.3.2

Menu: Room temperature reduced

[→ Main menu → User → Reduce]
Parameters
Setting range
Min / Max
Room tem-
5 - 40 °C
perature re-
duced
Tab. 7-7
Parameter in menu: "Room temperature reduced"
7.3.3

Menu: Room temperature absent

[→ Main menu → User → Absent]
Parameters
Setting range
Min / Max
Room tem-
5 - 40 °C
perature ab-
sence
Tab. 7-8
Parameter in menu: "Room temperature absent"
7.3.4

Menu: Hot water temperature, target

[→ Main menu → User → Hot water]
Parameters
Setting range
Min / Max
Hot water
35 – 70 °C
temp. setpoint
1
Hot water
35 – 70 °C
temp. setpoint
2
Hot water
35 – 70 °C
temp. setpoint
3
Tab. 7-9
Parameter in menu: "Hot water temperature, target"
Operating Instructions
30
Description
Target value of the room temperature in °C, which is valid for the 1st
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Target value of the room temperature in °C, which is valid for the 2nd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Target value of the room temperature in °C, which is valid for the 3rd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Description
Target value of the reduced room temperature in °C, which is valid for the
[Automatic 1] and [Automatic 2] time programs.
Description
Target value of the reduced room temperature in °C, which is valid for the
[Away] + [Vacation] time programs.
Description
Target value of the hot water temperature in °C, which is valid for the 1st
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Target value of the hot water temperature in °C, which is valid for the 2nd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Target value of the hot water temperature in °C, which is valid for the 3rd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
Factory
Incre-
Access
setting
ment
BE HF
20 °C
0.5 °C
E
E
20 °C
0.5 °C
E
E
20 °C
0.5 °C
E
E
Factory
Incre-
Access
setting
ment
BE HF
15 °C
0.5 °C
E
E
Factory
Incre-
Access
setting
ment
BE HF
15 °C
0.5 °C
E
E
Factory
Incre-
Access
setting
ment
BE HF
48 °C
0.5 °C
E
E
48 °C
0.5 °C
E
E
48 °C
0.5 °C
E
E
Daikin RoCon+ HP