5. Attach power supply connector from the range hood to the
connector on the blower motor assembly wiring box.
A
B
A. Blower motor assembly connector
B. Power supply connector from range hood
6. Reinstall the heat lamp panel using the screws removed in
the "Preparing the Internal Blower System," two in the sides
and either three in the back for the 36" (91.4 cm) model or
four in the back for the 48" (121.9 cm) model.
A. Screws: panel mounting (five) for 36" (91.4 cm)
models, (six) for 48" (121.9 cm) models
B. Panel: heat lamp
7. Reconnect the electrical connector to the heat lamp.
8. Go to the "Make Electric Power Supply Connection to Range
Hood" section.
A
A
B
Install Range Hood In-Line (External Type)
Blower Motor
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
See "Blower Motor System" in the "Accessories" section.
Prepare for Mounting the In-Line Blower System
The in-line blower system must be fastened to a secure
structure of the roof, ceiling, wall, floor, or new or existing frame
construction. The four holes on either the inlet (bottom) side or
the outlet (top) side of the blower must be used to mount the in-
line blower system to the structure.
NOTE: The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may be used
to span open areas between ceiling joists or roof rafters to aid
installation. This structure must be strong enough to support the
weight of the in-line blower system (50 lb [22.6 kg] minimum).
Prepare the In-line Blower System
WARNING
Excessive Weight Hazard
Use two or more people to move and install in-line
blower motor system.
Failure to do so can result in back or other injury.
1. Using two or more people, move the in-line blower motor
system to the mounting location.
2. Remove the 10 screws from the front cover of the in-line
blower motor housing and set them aside.
3. Remove the front cover of the in-line blower motor housing
and set it aside.
NOTE: To make the blower motor housing easier to mount,
the blower motor assembly can be removed. If you do not
want to remove the blower motor assembly, proceed to
"Install In-line Blower System" in this section.
4. Disconnect the motor electrical plug from the blower motor
assembly.
5. Remove the screws that secure the blower motor assembly
to the in-line blower housing and set them aside.
6. Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
D
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
A
B C
11