Cleaning, Maintenance And Ordering Of Spare Parts; Replacing The Power Cable; Carbon Brushes; Ordering Replacement Parts - EINHELL NEW GENERATION NMS 250 L Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Anleitung_NMS_250_L_SPK7:_
GB
7.4 Mitre cuts 0°-45° and rotary table 0°-45°
(Fig. 10)
The crosscut saw can be used to make miter cuts to
the left of 0°- 45° in relation to the work face and, at
the same time, 0° - 45° in relation to the stop rail
(double miter cut).
Lift the machine head (4) to its top position.
Undo the rotary table (8) by slackening the
locking handle (10) and pressing the latch (11).
Adjust the rotary table (8) by its handle (2) to the
required angle (see also Section 7.2).
Retighten the tightening screw (10) in order to
secure the turntable in place.
Undo the tightening screw (12) and use the
handle (2) to tilt the machine head (4) to the left
until it coincides with the required angle value (in
this connection see also section 7.3).
Screw the tightening screw (12) back down
again.
7.5 Laser function (Fig. 17)
You can switch the laser ON and OFF with the
switch (a).
The laser directs a beam onto the workpiece.
Extremely precise cuts can be made using the
laser function.
Replacing the battery (Fig. 18-19): Ensure that
laser (21) is switched off. Remove the battery
compartment cover (36). Remove the spent batteries
and replace them with new ones (2 x 1.5 V type R02,
LR 03 Micro, AAA). Check that the battery terminals
are positioned correctly. Close the battery
compartment again.

8. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
18
09.07.2010
7:28 Uhr
Seite 18
9. Cleaning, maintenance and ordering
of spare parts
Always pull out the mains power plug before starting
any cleaning work.
9.1 Cleaning
Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
We recommend that you clean the device
immediately each time you have finished using it.
Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts
of the equipment. Ensure that no water can seep
into the device.

9.2 Carbon brushes

In case of excessive sparking, have the carbon
brushes checked only by a qualified electrician.
Important! The carbon brushes should not be rep
laced by anyone but a qualified electrician.
9.3 Maintenance
There are no parts inside the equipment which
require additional maintenance.
Lubricate all moving parts at regular intervals.

9.4 Ordering replacement parts

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
10. Storage
Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing
temperature. The ideal storage temperature is
between 5 and 30 °C. Store the electric tool in its
original packaging.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

43.001.19

Table des Matières