Cleaning Suggestion
1. DAILY CLEANING
The ice shovel, door and the water dividing pipe
should be cleaned by yourself per each day. At the
end of every day, rinse the ice shovel and wipe the
both sides of the door with a clean cloth.
2. SEMI-MONTHLY CLEANING
The ice shovel, ice bin, water tank, the ice-full
detecting plate and the surface of the evaporator
are to be cleaned by yourself semi-monthly ac-
cording to interior cleaning program.
Trouble shooting
Problem
"Add water" indicator is on.
"Add water" indicator flashes
Water pump is working, but no water flow
out from the water dividing pipe
The transparency of the ice cube is not
very good
Ice cube shape is irregular
Ice cube is very thin
Ice cube is too thick
"Full" indicator is on
Ice making cycle is normal, but there is no
ice cube produced
3. SEMI-ANNUAL CLEANING
All the components & surfaces exposed to wa-
ter or ice cubes, like ice storage bin, water tank,
door, evaporator, water pump, silicone tube, wa-
ter dividing pipe, etc. should be cleaned by Using
Nu-Calgon Nickle Safe Ice-machine Cleaner per
each 6 months.
Possible
No water supply
Floating ball of the water level detecting
switch is blocked, can't be raised up
Water flows out from the water tank
Water flows out from the water drain pipe
of the water tank.
Water supplying hose breakdown, or water
flows in very slowly.
The little holes on the water dividing pipe
is blocked.
Water quality is bad
Water quality is not good or the water tank
is very dirty
The little holes on the water dividing pipe is
some blocked
Ambient temperature is too high
Air circulation around the unit is not good
Ambient temperature is too low
The ice storage bin is full of the ice cube.
The temperature of Ambient, or water in
water tank is too high
Refrigerant leakage
Cooling system tube is clogged
Solution
Check the main water supply pressure or
check the water supply hose is blocked or
not, adding the water pressure or cleaning
the hose necessary.
Clean the water tank and the water level
detecting switch.
Place the unit on the level position, not on
the slope.
Pull out the pipe and install back to the slot
of the water tank properly.
Check the main water supply pressure or
check the water supply hose is blocked or
not, adding the water pressure or cleaning
the hose necessary.
Clean these little holes.
Change the water supply, or use the water
filter to soften or filter the water.
Clean the water tank, and change with
new water.
Clean the water dividing pipe, make sure
all nine holes are unclogged.
Move the unit to low temperature space, or
lengthen the time of each ice making cycle.
Make sure there is more than 20CM space
between the unit back & front and the
obstacle
Reduce the time of each ice making cycle.
Take out some ice cube
Move to the place with temperature lower
than 32 centigrade, and change to the low
temperature water
Need the technical serviceman to maintain
Need the technical service person to
maintain