Error codes
H0 – Fig. 92
Wheel running conditions cannot be improved by optimisation.
H1 – Fig. 93
Further optimisation not recommended but feasible.
H2 – Fig. 94
Weight minimisation is recommended, optimisation can
achieve no further improvement.
H3 – Fig. 95
Optimisation not recommanded.
H20 – Fig. 96
Correction plane cannot be re-located with the gauge arm for
distance and rim diameter.
D
Measure the correction plane and switch to dynamic
unbalance reading.
H21 – Bild 97
The indexed position is not the one for the correction plane in
which the adhesive weight is to be fitted with the gauge arm.
D
Index the correct position for this correction plane prior to
fitting the adhesive weight.
Operation manual geodyna 4300 – 9512 150
H0 – Fig. 92
Impossible d'améliorer la stabilité de marche de la roue au
moyen d'une optimisation.
H1 – Fig. 93
Déconseillé de continuer l'optimisation qui reste pourtant pos-
sible.
H2 – Fig. 94
Recommandé de minimiser la masse; continuer à optimiser
n'apporte pas d'amélioration.
H3 – Fig. 95
Optimisation non recommandée.
H20 – Fig. 96
Le plan de correction ne peut pas être retrouvé avec la pige de
mesure pour écart et diamètre de jante.
D
Mesurer le plan de correction et vérifier que le balourd
dynamique soit affiché.
H21 – Fig. 97
La position d'orientation ne correspond pas au plan de correc-
tion sur lequel la masse adhésive doit être placée à l'aide de la
pige de mesure.
D
Pour placer la masse adhésive, orienter le plan de cor-
rection adéquat.
Mode d'emploi geodyna 4300 – 9512 150