• Setting the barking detection sensitivity

Your dog's barking is detected by one of the contact points which sense the vibrations of his vocal cords (See Diagram 1).
Setting the barking detection sensitivity is a very important preliminary operation. In fact, this setting determines the
correct operation of the product.
It ensures detection of any barking but helps avoid unnecessary detection. The detection must therefore be sufficiently
sensitive but not overly sensitive.
In the factory, detection sensitivity is set on level 5 (medium sensitivity).
To adapt the detection sensitivity to the barking strength of your dog, turn the button located on the front of the collar
according to the sensitivity you wish (See Diagram 1).
CAUTION: the adjustment button has a stop for the minimum sensitivity (0) and for the maximum sensitivity (10).
Level 0 = minimum barking detection sensitivity (only strong barks will be detected and activate the product)
Level 10 = maximum barking detection sensitivity (light barks will activate the product)

• Checking/Replacing battery

The battery condition is checked in 3 distinct occasions:
awhen switching On the collar:
5 beep sounds + indicator light flashes in red 5 times (instead of 1 beep sound + 1 flash) = weak battery
awhen the collar is On:
indicator light flashes in red 5 times every 5 seconds (instead of 1 time every 5 seconds) = weak battery
awhen switching Off the collar:
5 beep sounds + indicator light flashes in red 5 times (instead of 3 beep sounds + permanent red) then the collar goes out =
weak battery
Prepare to replace the battery.
When the battery is too weak, the product switches to safety mode and the system locks up.
Due to greater use during your dog's training, the first battery may not last as long as replacement batteries.
EYENIMAL advises to use the same type and same brand of batteries as those supplied in your new purchased product.
Other brands of batteries may not operate, or may not be completely compatible with your product.
You can purchase the suitable batteries from EYENIMAL or from your distributor.
Replace the old battery as follows:
aUnscrew the battery cover using a coin.
aRemove the old battery.
aInsert the new battery (Lithium 3-V CR2) paying attention to follow polarity indicated under the collar (See. Diagram 2).
aRetighten the battery cover using a coin. A beep sound is emitted indicating the correct installation of the battery.
If you do not hear any beep sound when retightening the battery cover, remove the battery immediately from its
housing. Check the polarity before trying again.
NOTE: when changing the battery, there can remain some power in your collar. In that case, the collar does not emit any
beep sound when you retighten the battery cover after inserting the battery. To make sure it operates properly and that the
battery is correctly installed, turn your collar on with the magnetic key.
After changing the battery, next time you will switch on the collar, it will be in the last selected operating mode.
)