PerfectPower
9

Using the inverter

A
NOTICE!
If no circuit breaker is present: If the inverter is connected to the
external mains voltage, the 230 V output socket is earthed.
If there is no external mains voltage, the inverter is only connected to the
battery (DC operation). In this case, the 230 V output socket is not
earthed, but safeguarded with the protective insulation instead.
A
NOTICE! Risk of short circuit!
You must switch on the inverter first before switching on the consumers.
When using the inverter, observe the following instructions:
• If the battery voltage drops below the alarm value during operation (see "Low
voltage alarm" in chapter "Technical data" on page 21), a warning signal sounds
and LED "UVP" (fig. 1 7, page 3) lights up.
• If the battery voltage drops below the shutdown value (See "Low voltage
shutdown" in chapter "Technical data" on page 21), the inverter switches off.
• If the inverter overheats, it switches off and LED "OLP" (fig. 1 6, page 3) lights
up.
After it cools down, the inverter automatically switches back on.
• When operating the inverter at a high load for lengthy periods, it is advisable to
start the engine in order to recharge the vehicle battery.
➤ Connect your consumer to the 230 V output (fig. 1 4, page 3).
You can also connect a socket distribution system.
9.1
Using the inverter without remote control
➤ Set the main switch (fig. 2 1, page 3) to
– "ON" to switch the inverter on
– "OFF" to switch the inverter off
✓ LED "POWER" lights up when the inverter is switched on.
EN