NOTICE!
• Incorrect polarity will blow an internal fuse which has to be replaced
by the Dometic service. Additionally the electronics may be dam-
aged.
• Make sure that the inverter is operated with the following voltage
only:
– DSP212, DSP412: 12 Vg
– DSP224, DSP424: 24 Vg
➤ Connect the inverter as shown:
– Connecting the battery:
DSP212, DSP224: fig. 5, page 5
DSP412, DSP424: fig. 6, page 5
– Connecting load: fig. 7, page 6
Connect external switch to turn device on and off (DSP412, DSP424 only)
I
NOTE
The inverter is switched on when the external or the main switch
(fig. 2 1, page 3) is switch on. If the inverter shall be controlled via
external switch only, the main switch has to be switch to position "0".
➤ Connect the external switch as shown (fig. 8, page 6).
8

Using the inverter

!
CAUTION!
When connecting the load observe the applicable regulations.
8.1
Switching on the inverter
➤ Switch the inverter on by pressing the switch (fig. 2 1, page 3) on the device
(position "I") ...
➤ ... or (DSP412, DSP424 only) switch on the inverter using the external switch
(optional).
✓ The blue Status LED lights up (fig. 2 2, page 3).
✓ The power consuming device is supplied with voltage.
EN
Using the inverter
17