19. Replacing the Flow Rate Regulator

19.1 Loosen the grub screw using a hollow hexagon wrench.
19.2 Pull the shower head from the connection spigot.
19.3 Remove the circlip with an appropriate pliers for inward circlips.
19.4 Pull out the flow rate regulator with a flat nose pliers.
19.5 Replace the flow rate regulator. Note details provided in the table.
Flow rate
0.15 l/s (orange)
0.20 l/s (red)
Important!
Ensure correct installation orientation of the flow rate regulator. The brace must face
in the direction of the head piece.
19.6 Insert the flow rate regulator and secure with the circlip.
a: Brace
b: Flow direction
19.7 Push the shower head onto the connection spigot.
19.8 Tighten the grub screw using a hollow hexagon wrench.

20. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Flow rate regulator
FAR Order No. 2000104782
FAR Order No. 2000104783
Cause
– Stop-valve is closed
– Voltage supply interrupted
– Water supply interrupted
– Grit filters are clogged with dirt
– Piezo-button faulty
– Solenoid valve faulty
– Solenoid valve dirty
– Solenoid valve faulty
– Supply pressure too low
– Grit filter is clogged
– Water volume regulator is not fully
opened
– Shower head calcified
- 11 -
Remedy
➯ Open it
➯ Restore it
➯ Restore it
➯ Replace them
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Check it
➯ Clean it
➯ Open it
➯ Clean it